Certified structured cabling

Certified network cabling, the guarantee of performance

Installation, patching and certification of your RJ45 copper cabling (Cat 5e, 6, 6A): every link is tested and certified to guarantee your network's performance and reliability over time.

Our services

From installation to certification

Certified copper cabling

Cat 5e, 6 and 6A cabling installed to current standards.

Fluke testing & certification

Every link is tested and certified with professional measurement equipment.

Patching & labelling

Neat patch cabinets, labelled and identified cables for straightforward maintenance.

Standards & compliance

Installation compliant with current ISO/IEC 11801 and EIA/TIA standards.

Manufacturer warranty

Certification eligible for extended warranties from cabling system manufacturers.

Acceptance testing & documentation

A complete acceptance file handed over when your installation is delivered.

Technician certifying RJ45 outlets on a patch panel with a Fluke Networks cable certifier
On-site acceptance testing: every RJ45 outlet is certified, measured and documented.
Why certify your cabling

The reliable foundation of your whole network

Uncertified cabling is a common source of network faults that are hard to diagnose. Certification guarantees that every link meets the expected performance, at handover and over time.

  • Performance measurements on every link (attenuation, crosstalk, length)
  • Detailed certification report, socket by socket
  • Faults detected before go-live
  • A solid foundation for telephony, Wi-Fi and everything else on your network
The deliverable

See the report before you award us the job

Plenty of companies say they certify. Few show what they hand over. Here is a complete report from a real site — only the client name has been removed.

27pages
24links tested
20passing
4failing

Why four links fail. Because that is what certification is for. A tester that never finds anything proves nothing. A FAIL is a fault found before go-live — connector to redo, patch cord or module to replace — when fixing it costs minutes, rather than an intermittent fault to chase six months later.

  • One sheet per outlet: length, insertion loss, NEXT, ACR-F, return loss, wire map
  • Every measurement timestamped and tied to the tester serial number and calibration date
  • Measured with a Fluke Networks DSX-5000, calibrated 19/02/2026 — LinkWare PC 12.0
Download the report (PDF, 570 KB)

No form, no email address required.